Policies  Business Hours   |  Inquiry Cart   | 
Great Selection  Low Prices  Fast Delivery 
Welcome to Matrix Electronics & Communication! To Place your order contact us on 02135674481, 03002785860. Timings {Monday-Saturday 11am-8:30pm}.
DSO1062B Hantek
Description

DSO1062B Hantek

High Bandwidth 60MHz-200MHz Oscilloscope, 1GS/s sample rate, and 6000

Counts DMM with analog bargraph. 
 

• 1M Memory Depth. 
• High Refresh Rate (2500 frames). 
• Large 5.6 inch TFT Color LCD Display; High Resolution(640*480); Dual-Window
   Design --More clear, More Detailed. 

• One-touch automatic setup optimizes the position, range, timebase, and triggering
   to assure a stable display of virtually any waveform. 

• Easy-to-use pop-up menu with built-in multi-language help system. 
• 32 Automatic Measurements. 
• Waveform Math: Add, Subtract, Multiply, and Divide. 
• Store and recall over. 
• Automatic cursor tracking measurements. 
• XY Mode. 
• Built-in FFT function converts a time-domain signal into its frequency components
   to measure harmonic content and distortion in systems. 

• Waveform Recorder to capture/replay input waveforms from CH1 and CH2 with
   a maximum record length of 1000 frames. 

• Pass/Fail function compares a stored waveform to an unknown input. 
• Average Mode for smoothing waveforms. 
• Square Wave Output (2V, 1kHz) for probe adjustment. 
• USB Host/Device 2.0 full-speed interface ,support removeable disk, LAN Optional
  ,Easy to control by PC or long-distance. 

• Dimensions (mm):240(L)x165(W)x50(H), be carried easily.


Parameters:


1.Acquisition
 

Sample Modes:Real-Time Sample: 1GS/s; Equivalent Sample: 25GS/s


2.Acquisition Modes

 

Normal :Normal data only

Peak Detect :High-frequency and randon glith capture
Average :Wavefom Average, selectable 4,8,16,32,64,128 


3.Inputs Inputs Coupling :AC, DC, GND

 

Maximum Input Voltage :CAT I and CAT II: 300VRMS (10×), Installation Category;

CAT III: 150VRMS (1×);Installation Category II: derate at 20dB/decade above

100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms,

peak value must be less than 450V. Excursion above 300V should be of less

100ms duration. RMS signal level including all DC components removed through

AC coupling must be limited to 300V. If these values are exceeded, damage to

the oscilloscope may occur.

 

4.Horizontal


Sample Rate Range :500MS/s--1GS/s

SEC/DIV Range:4ns/div~2000s/div,

Position Range :4ns/div to 8ns/div; (-8div x s/div) to 40ms;20ns/div to 80µs

/div;(-8div×s/div)to 40ms;200µs/div to 40s/div; (-8div×s/div)to 400s;


5.Vertical


Bandwidth : 60MHz

Rise Time at BNC( typical) : 5.8ns

DC Gain Accuracy :±3% for Normal or Average acquisition mode, 5V/div to

10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div

 

6.Mechanical

 

Size :Length 245mm; Width 163mm; Height 52mm

Weight :1.2KG(without Packing)

DSO1062B Hantek

  • Model : Hand Held Portable Multimeter Oscilloscope 60MHz
  • Availability: In Stock